医院医疗污水处理工程
设 计 方 案(80T/d)
目 录
公司简介··················································2
一、概述··················································3
二、污水的排放水量········································3
三、污水水质及排放标准····································3
四、设计原则及设计标准和规范······························4
1、设计原则···············································4
2、设计标准和规范·········································4
五、污水处理工艺方案······································5
1、处理工艺的确定·········································5
2、工艺流程图·············································5
3、SBR工艺的特点··········································5
六、处理工艺说明··········································6
七、主要处理构筑物技术参数································7
八、设计处理效果··········································8
九、机械设备的配置及报价··································9
十、售后服务··············································9
公 司 简 介
一、概述
医院污水由来自住院部、门诊室、实(化)验室、食堂、浴室、卫生间、试剂室、洗衣房等场所排放的污水组成。该污水是一种低浓度污水,水质与一般生活污水类似,其中除含有有机的和无机的污染物,如各种药物、消毒剂、解剖遗弃物等污染物,还含有大量病菌、病毒和寄生虫,成份较为复杂。尤其是传染病区和结核病区的污水中,含有多种传染性病菌、病毒,如肝炎病毒、结核菌和痢疾菌等。此外,在设有同位素诊疗室的医院污水中还含镭226、磷、金198、碘131等放射性物质。与工业废水和生活污水相比,它具有水量小,污染力度强的特点。这些病毒、病菌和寄生虫卵在常温环境中具有较强的存活率和适应性,在污水中能够存活较长时间。如任其排放,必然会污染水源,传播疾病,故必须将这些污染消灭在源头。
二、污水的排放水量
《医院污水处理设计规范》提出的综合医院排水量为:
1、 设备比较齐全的大型医院平均日污水量为:400-600L/(床·d),k = 2.0-2.2
2、 一般设备的中小医院,平均日污水量为:300-400 L/(床·d),k = 2.2-2.5
3、 小型医院平均日污水量为:250-300L/(床·d),k = 2.5
k — 小时变化系数
根据客户提供的数据,本工程污水处理量为:80吨/天。
三、污水水质及排放标准
1、污水源水水质:
编 号 | 污 染 物 质 | 污水原水水质量 | 单 位 |
1 | PH | 6-9 | |
2 | SS | 150-300 | mg/l |
3 | CODcr | 300-350 | mg/l |
4 | BOD5 | 180-210 | mg/l |
5 | NH3-N | ≤45 | mg/l |
6 | TP | ≤4 | mg/l |
7 | 细菌总数 | >160×104 | 个/l |
由上表可知该类污水属于可生化性污水。
2、排放标准:
污水经过处理后排放应达到《医疗机构水污染物排放标准》GB18466-2005中相关要求。既下表
《医疗机构水污染物排放标准》
编 号 | 污 染 物 质 | 出水水质标准 | 单 位 |
1 | PH | 6-9 | |
2 | SS | 20 | mg/l |
3 | CODcr | 60 | mg/l |
4 | BOD5 | 20 | mg/l |
5 | NH3-N | ≤15 | mg/l |
6 | 总余氯 | 0.5 | mg/l |
7 | 细菌总数 | <500 | MPN/l |
8 | 动植物油 | 5 | mg/l |
9 | 石油类 | 5 | mg/l |
10 | 阴离子表面活性剂 | 5 | mg/l |
四、设计原则及设计标准和规范
1、设计原则
1.1 遵守国家对环境保护、医院污水治理制定的法规、标准及规范,服从医院的总体规划, 执行各种相关的标准和规定。
1.2 因地制宜地选用污水处理工艺,做到技术先进、实用、安全可靠、处理效果稳定,经处理后水质达标,并减少占地面积。
1.3 在达标排放的基础上,在供水日趋紧张,用水费用不断上涨的情况下,考虑中水回用。
1.4 尽可能地减少污水处理站对周围环境的不良影响,防止二次污染。
1.5 适当地考虑自动化操作,以简化操作管理和减轻工人的劳动强度,并易于维护保养。
1.6 节约能源,最大限度降低运行费用,工程投资少,占地面积小,见效快。
1.7 尽量采用新材料、新产品以延长设备的使用寿命
2、设计标准和规范
2.1 《污水综合排放标准》(GB8978-1996);
2.2 《医院污水处理设计规范》(CECS07:88);
2.3 《室外排水设计规范》(GBJ14-87);
2.4 《建筑给水排水设计规范》(GBJ15-88);
2.5 《城市区域环境噪音标准》(GB3096-93)
2.6 《给排水工程结构设计规范》(GBJ69--84)
2.7 《生活杂用水水质标准》(GJ25.1-89)
2.8 《医疗机构水污染物排放标准》GB18466-2005
五、污水处理工艺方案
1、处理工艺的确定
根据GB18466-2005《医疗机构污染物排放标准》、CECSO7-2004《医院污水处理设计规范》、和《医院污水处理技术指南》等,国家对于医疗污水的技术、规范、标准的一系列要求。医疗污水的处理,必须综合考虑污水中细菌、病毒的种类和数量,以及污水的理化指标和毒理指标,污水的排向和受纳水体对水质的具体条件所要求的处理效果,来确定具体的处理工艺及其排放水质。
选用活性污泥法的间歇式活性污泥法——SBR工艺,处理过程为:SBR+消毒。
2、工艺流程图
.
.
.